Nice Road Barriers

Electromechanical road barriers with clear openings from 2.3 to 9 metres, 24 VDC gearmotors, IP54 cabinets and duty ratings up to 500 cycles per hour.

Nice S-Bar Electromechanical Road Barrier System

Nice road barriers are built around 24 VDC gearmotors in steel or stainless cabinets, and the range is selected primarily by clear opening and required duty. S-Bar covers openings to 4 metres, M-Bar spans 2.32 to 4.82 metres across the M3BAR, M5BAR and M7BAR models, and L-Bar with the L9BAR handles 7 to 9 metres. The Wide series covers 4 metres on Wide S and Wide M, with Wide L reaching 6 metres in a 3 plus 3 configuration using the XBA9 accessory.

Duty rating is where the specification usually gets decided, because a barrier at a busy car park entrance cycles far more often than a perimeter gate. M-Bar and L-Bar models are rated from 500 cycles per hour on the smallest through 350, 200 and 150 on the larger booms, while the Wide series runs at 100 to 300 cycles per hour and S4BAR at 100. Torque follows the same progression, from 100 Nm up to 400 Nm on L-Bar.

Opening times range from 2.5 seconds on the shortest M-Bar boom to 12 seconds on the longest L-Bar configuration, with Wide models opening from 3.5 to 5 seconds and S4BAR from 4 seconds. All are supplied on 230 V mains with a 24 VDC gearmotor, which allows battery backup through the matching PS series battery to keep the barrier operating through a mains failure.

Cabinets are steel with cataphoresis treatment and paint, or AISI 304 stainless steel where the environment demands it, an option worth taking seriously on coastal sites in the Eastern Province. Protection is IP54 on M-Bar, L-Bar and Wide, and IP44 on S4BAR, with an operating range of minus 20 to plus 55 degrees C on most models. M-Bar and L-Bar include an encoder alongside electromechanical limit switches.

A note on durability figures: Nice does not publish an MCBF or a cycles-per-day rating for these barriers. The manuals instead provide a severity-index durability graph with worked examples, which means expected life depends on boom length, accessories and duty in a given installation. Stebilex supplies, installs and services Nice barriers across Saudi Arabia from Al Khobar and Riyadh and can run that calculation against your traffic profile.

Features

  • Clear openings from 2.32 metres up to 9 metres across the range
  • 24 VDC gearmotor on 230 V mains, with battery backup options
  • Duty ratings up to 500 cycles per hour on the smallest M-Bar boom
  • Torque from 100 Nm up to 400 Nm depending on model
  • IP54 protection on M-Bar, L-Bar and Wide series
  • Steel with cataphoresis and paint, or AISI 304 stainless cabinets
  • Encoder plus electromechanical limit switches on M-Bar and L-Bar
  • Operating range of minus 20 to plus 55 degrees C on most models

Specifications

Current familiesS-Bar (S4BAR, S4BARI), M-Bar (M3BAR, M5BAR, M7BAR), L-Bar (L9BAR), Wide S, Wide M, Wide L
Clear opening (M-Bar / L-Bar)2.32-2.82 m, 3.17-4.82 m, 5-7 m and 7-9 m depending on model
Clear opening (Wide)4 m on Wide S and Wide M; 6 m on Wide L in a 3 plus 3 configuration with XBA9
Clear opening (S4BAR)4 m
Opening time (M-Bar / L-Bar)2.5-4 s, 3-6 s, 6-10 s and 8-12 s depending on model
Opening time (Wide)4 s (Wide S), 3.5 s (Wide M), 5 s minimum (Wide L)
Opening time (S4BAR)4 s or more
Power supply230 V mains with 24 VDC gearmotor (Wide also available as /V1 at 120 V)
TorqueM-Bar and L-Bar 100 / 200 / 300 / 400 Nm; Wide 100 / 140 / 200 Nm; S4BAR 100 Nm
Duty ratingM-Bar and L-Bar 500 / 350 / 200 / 150 cycles per hour; Wide 100 / 300 / 200 cycles per hour; S4BAR 100 cycles per hour
Cabinet (M-Bar / L-Bar)Steel with cataphoresis and paint, or AISI 304 stainless; 400 x 299 x 1,215 mm high; 80-98 kg
Cabinet (Wide)Galvanised and painted steel, or AISI 304 stainless; 280 / 320 / 420 mm wide; 40-54 kg
Cabinet (S4BAR)Steel or stainless; 330 x 179.5 x 1,146 mm high; 35 kg
Protection ratingIP54 on M-Bar, L-Bar and Wide; IP44 on S4BAR
Operating temperature-20 to +55 degrees C on M-Bar, L-Bar and Wide; -20 to +50 degrees C on S4BAR
Control unitBCU1 (M-Bar and L-Bar), WIA20 (Wide), XBA20 (S-Bar)
EncoderFitted on M-Bar and L-Bar with electromechanical limit switches
Battery backupPS224 (M-Bar and L-Bar), PS324 (Wide), PS124 (S-Bar)